New machines and automation
Cycle sequences, interlocks, alarms and manual and automatic modes: we turn the required behaviour into a clear, commented and documented PLC program.
Programming of programmable logic controllers (PLC) for new and existing machines: Schneider Electric, Allen-Bradley, GE and Panasonic. Machine logic, changes to existing programs and replacement of obsolete PLCs, consistent with the electrical schematic and electronics.
Cycle sequences, interlocks, alarms and manual and automatic modes: we turn the required behaviour into a clear, commented and documented PLC program.
New functions, recipes, process changes or fixes on a machine already in service, without altering what works today.
When the controller is discontinued, we move the logic to current hardware while keeping inputs, outputs and machine behaviour the same.
Industrial retrofit →We work with PLCs from several manufacturers: Schneider Electric, Allen-Bradley (Rockwell Automation), GE and Panasonic. The program is written in the IEC 61131-3 languages supported by the chosen controller.
We list inputs, outputs, sensors, actuators and required functions, starting from the electrical schematic, the cycle description or the existing program.
We agree on sequences, states, alarms and interlocks before writing code, so the expected behaviour is written down and verifiable.
We write the program and test it, where possible, in simulation or on the bench before installing it on the machine.
Testing on the machine and delivery of the commented program, the I/O list and a backup copy.
Schneider Electric, Allen-Bradley (Rockwell Automation), GE and Panasonic. If your machine uses another brand, say so in your request: we assess case by case whether we can help.
It depends on the controller and on how the program is protected. If it cannot be read, the logic is rebuilt from the electrical schematic, the signals and the machine behaviour: this is reverse-engineering work, described on the industrial retrofit page.
Yes. We design and digitise electrical schematics, so the PLC program and the schematic stay consistent with each other.
Tell us the PLC brand and model, what the machine must do and the documentation you have. We define the scope of the work with you.
Describe your machineSchneider Electric, Allen-Bradley, Rockwell Automation, GE and Panasonic are trademarks of their respective owners, cited only to indicate the controllers we work on. Moxá Design is not affiliated with or authorised by the manufacturers.